Product Details:Capacity (KLD) | 50 KLD |
AMC Provided | Yes |
Application Industry | Residential & Commercial Building |
Secondary Treatment Technology | Mixed Bed Bio Reactor(MBBR) |
Feed Flow Rate | 50 m3/day |
Installation Type | Prefabricated |
Feed Flow Rate(m3/day) | 0-50 m3/day |
Water Pump Power | 1.5 KW |
Phase | Three Phase |
Power Source | Electric |
Automation Grade | Semi-Automatic |
Body Material | Stainless Steel,FRP |
Additional Information:
Approx. Rs 1.2 Lakh / PieceGet Latest Price
Product Details:Minimum Order Quantity | 1 Piece |
Capacity (KLD/MLD) | 50 KLD |
Capacity (KLD) | 50 KLD |
AMC Provided | Yes |
Application Industry | Residential & Commercial Building |
Treatment Technology | Mixed Bed Bio Reactor(MBBR) |
Feed Flow Rate(m3/day or m3/hr) | 0-50 m3/day |
Inlet Flow Rate(m3/day) | 50 m3/day |
Material of Construction | Mild Steel |
Water Pump Power | 1.5 KW |
Automation Grade | Semi-Automatic |
Impurities To Be Removed | Oil & Grease, Turbidity |
Deliver Type | PAN India |
Warranty | 1 Year |
Warranty of Core Components | 1 Year |
I Deal In | New Only |
Treatment Stages | Tertiary Treatment, Secondary Treatment, Preliminary Treatment, Primary Treatment |
Air Blower Count | 2 Blowers |
Air Blower Power | 1 KW |
Control Module | Available |
Additional Information:
Approx. Rs 3.2 Lakh / PieceGet Latest Price
Product Details:Minimum Order Quantity | 1 Piece |
Capacity (KLD/MLD) | 50 KLD |
AMC Provided | Yes |
Application Industry | Residential & Commercial Building |
Treatment Technology | Membrane Bioreactor(MBR) |
Feed Flow Rate(m3/day or m3/hr) | 51-100 m3/day |
Water Pump Power | 1 KW |
Automation Grade | Automatic |
Impurities To Be Removed | Turbidity, Oil & Grease, TDS, Dissolved Minerals |
Space Area Required(l*b*h in Feets) | As Per Design |
Deliver Type | PAN India |
Material Of Construction | Mild Steel |
Warranty | 1 Year |
Warranty of Core Components | 1 Year |
I Deal In | New Only |
Treatment Stages | Preliminary Treatment, Secondary Treatment, Primary Treatment |
Air Blower Count | 2 Blowers |
Air Blower Power | 1 KW |
Control Module | Available |
MBR Sewage Treatment Plant for textile industry also known as STP is a Sewage treatment plant (STP) that is used to treat wastewater. It's mostly used in industries like pharmaceuticals, textiles, and chemicals where extreme water contamination is a possibility. The effluent treatment plant falls under this category as their common name etp plant, etp, effluent sewage treatment plants, common effluent treatment plant, Effluent Treatment Plant of Dairy, Effluent wastewater treatment plant, effluent treatment plant textile industry.
ETP plays a significant role in the treatment of industrial waste water as well as domestic sewage. Organic matter, inorganic matter, heavy metals, oil & grease, suspended particles, and other contaminants are treated in the wastewater treatment process of an ETP plant. Chemical treatment, biological treatment, a combination of chemical and biological treatment, and thermal treatment are the several types of wastewater treatment plants.
Effluent treatment plant are called in this way as their common name WWTP for Rice Mill, rice mill effluent treatment plant, ETP for Rice Mill, etp, biomedical liquid waste treatment system, Physico-Chemical etp in india, Activated Charcoal treatment etp, industrial etp, dairy etp, effluent treatment plant system, Commercial Effluent Treatment Plant, Effluent Treatment Plant, effluent treatment plant textile industry, Rice Mill ETP, effluent sewage treatment plants, common effluent treatment plant, Effluent Treatment Plant of Dairy Wastewater, wastewater treatment plant
How does STP Plant Work?The conceptual approach of the treatment includes the removal of suspended particles, dissolved organic matters and handling of sludge for disposal. Different processes involved are:
EQUALISATION: The equalization tank's purpose is to balance the raw effluent from various processing units. The wastewater is collected in an existing mixed effluent tank and pumped to an existing aeration tank, which also functions as an equalization tank. The floating aerator is used to homogenize the effluent before it is pumped to the neutralization tank for treatment.
pH CONTROL: The pH value of effluent should be between 5.5 and 9.0, according to the Bureau of Indian Standards (BIS).pH neutralization is used to modify the pH of wastewater.
For waste that is acidic (low pH): Bases are used to modify the pH of a solution.
In the case of alkali waste (high pH): Acids are used to modify the pH of a solution.
COAGULATION: Coagulation is a technique that involves adding liquid aluminium sulphate to untreated water. This causes tiny dirt particles to stick together after mixing. This collection of particles combines to generate larger, heavier particles that are easily removed through settling and filtration.
SEDIMENTATION: Water travels slowly in this process, causing the heavy particles to settle to the bottom. Sludge is the term for the particles that gather at the bottom of a container.
FILTRATION: Filtration is the process of passing water through a filter that removes particulates. The filters are made out of sand and gravel layers. Backwashing is required to clean these filters on a regular basis.
DISINFECTION: Before entering the distribution system, water is disinfected. Chlorine is used to disinfect and decontaminate water.
SLUDGE DRYING: Sedimentation collects and settles down solids, which are then transported to drying beds. When the sludge thickness reaches around 300 mm, the sludge charging should be stopped, and the bed should be segregated to allow natural evaporation to dry it off. This takes approximately ten days.Additional Information:
Approx. Rs 3.2 Lakh / PieceGet Latest Price
Product Details:Minimum Order Quantity | 1 Piece |
Capacity | 50 KLD |
Capacity (KLD/MLD) | 50 KLD |
AMC Provided | Yes |
Application Industry | Residential & Commercial Building |
Treatment Technology | Mixed Bed Bio Reactor(MBBR) |
Inlet Flow Rate | More than 1000 m3/hour |
Feed Flow Rate(m3/day or m3/hr) | 51-100 m3/day |
Installation Type | Prefabricated |
Material of Construction | Mild Steel |
Impurities To Be Removed | Turbidity, Oil & Grease, TDS, Dissolved Minerals |
Deliver Type | PAN India |
Treatment Stages | Primary Treatment, Preliminary Treatment, Secondary Treatment, Tertiary Treatment |
Country of Origin | Made in India |
In Industrial Sectors water demand is very high and water normally used for manufacturing and processing units generates large amounts of waste water. In industrial sectors supply of domestic water requirement is limited & in big industrial units at a time 700 – 1000 people work together in a factory. With processing wastewater, sewage water is also generated in industrial facilities. Chemtronics offers a Green STP/AD+ for Industrial facility to treat sewage water up to reclaimed water which we can use for non potable application. Chemtronics gives the appropriate solution needed an efficient way to deal with daily sewage waste water.
This stage converts organic matter in sewage into stable forms through biological activities, resulting in secondary sedimentation. Common approaches are trickling filters and activated sludge methods.
Trickling filters comprise an enclosed tank with a bed of bricks and a layer of microorganisms. The effluent enters the tank through an inlet and trickles over the bed layer by sprinklers. Microbial activities oxidize the organic matter in the effluent, resulting in the removal of fine solids, formation of sludge and an effluent with less organic solids.
Activated sludge method involves the addition of a mixture of active microorganisms to sewage, followed by aeration and agitation. The aerobic conditions and microbial actions oxidize the organic solids resulting in coagulation, flocculation and settling of solids. Activated sludge produces a clear liquid without foul odor.
Tertiary treatmentThe effluent then undergoes tertiary treatment/disinfection by incorporation of UV radiation or chlorination. Other methods such as sand filters and reverse osmosis may also be used instead for this stage of treatment, depending upon the nature of the sewage and the effluent from secondary treatment.
We also deal in mbr sewage treatment plant,
activated sludge process stp,
MBBR technology sewage treatment plant,
Non electric sewage treatment plant,
Sewage treatment plant for small hospitals,
Industrial sewage plant,
Sequential Batch Reactor sewage treatment plant.
Additional Information:
Explore More Products
© India Water Life. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited